Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Medical Journal of Chinese People's Liberation Army ; (12): 70-75, 2017.
Article in Chinese | WPRIM | ID: wpr-618375

ABSTRACT

Objective To compare the ear baric function between 4000m altitude chamber test with inhaling air and 6900m altitude chamber test with inhaling pure oxygen.Methods Eleven healthy male volunteers attended two tests as two groups by self-comparison. As the air group the volunteers inhaled air at 4000m, while as the pure oxygen group they inhaled pure oxygen at 6900m altitude, and the time interval between the two tests was more than two weeks. During the test, the volunteers breathed air or pure oxygen at random for 1h, and then were exposed at a speed of 20m/s to the target altitude for 5min. Hereafter they were sent back to the ground at the same speed. The changes of subjective symptoms, degree of tympanic congestion, acoustic immitance index and pure-tone auditory threshold were recorded before and after the test. The acoustic impedance index and pure-tone threshold were statistically analyzed.ResultsFour volunteers (4 ears) in air group and 7 volunteers (7 ears) in pure oxygen group reported ear pain in altitude chamber exposures, respectively. The pain-triggering altitude was higher in the pure oxygen group. Immediately after tests, there were 3 (3 ears) and 5 volunteers (5 ears) with Ⅲ degree congestion of the tympanic membrane in the two groups respectively. Four volunteers (6 ears) developed gradually aggravated hemorrhages after altitude exposure. And the tympanic membrane congestion difference between groups was statistically significant at 3 and 24h after tests (P<0.01). The type A tympanogram appeared in 11 (15 ears) and 11 (14 ears) volunteers respectively immediately after tests. The increase of static compliance value was significantly greater in pure oxygen group than in air group immediately after tests (P<0.05), the decrease of middle ear pressure was more significant in pure oxygen group than in air group at 3 and 24h after tests (P<0.05). Both the two altitude exposure tests resulted in eustachian tube dysfunction. At 3 and 24h after the tests, the increase of individual frequency pure-tone threshold was significantly higher in pure oxygen group than in air group (P<0.05).Conclusion Breathing pure oxygen and lifting height could increase the screening degree of ear baric function test in hypobaric chamber, and have greater influence on degree of tympanic congestion, acoustic immittance and pure-tone auditory threshold in 24 hours.

2.
Journal of Biomedical Engineering ; (6): 702-707, 2011.
Article in Chinese | WPRIM | ID: wpr-359195

ABSTRACT

10 male subjects participated in the environmental simulation study to evaluate the operation ergonomics at high-temperature in the cockpit. Grip strength, perception, dexterity, reaction and intelligence were measured respectively during the tests at 40 degrees C and 45 degrees C, simulating the high-temperatures in a simulation cockpit chamber. Then the data obtained were compared to the combined index of heat stress (CIHS). The average values of each item of the subjects' performance at the two different temperatures are compared. The results indicated that CIHS exceeded the heat stress safety line after 45 min at 40 degrees C, grip strength decreased by 12%, and perception increased by 2.89 times. In contrast, at 45 degrees C, CIHS exceeded the safety line after 20 min, grip strength decreased by 3.2%, and perception increased by 4.36 times. However, Finger dexterity was less affected. Reaction ability was first accelerated, and then slowed down. The error rate in the intelligence test increased to a greater extent. At the high temperatures, the minimum perception was the most affected, followed by grip strength, reaction and finger dexterity were less affected, while the intelligence did not decline, but rise.


Subject(s)
Adult , Humans , Male , Young Adult , Aerospace Medicine , Aircraft , Computer Simulation , Ergonomics , Heat Stress Disorders , Hot Temperature
3.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-583495

ABSTRACT

The apparatus introduced in this paper can be used to measure and record the realtime environmental parameters and such physical information of individual protection equipment as the temperature,thermal current and thermal insulating value.The apparatus has several advantages including high accuracy,practicability,reliability and easy to operate.

SELECTION OF CITATIONS
SEARCH DETAIL